Abstract
This paper proposes a controllable resistive type fault current limiter for soft and fast starting of induction motors (IMs) based on the primary resistance method. Two methods of constant current and minimized torque pulsations starting for the proposed FCL are presented. A comparison is done and it is shown that method of minimized torque pulsations by the proposed structure leads to a fast and soft starting for IM. Analytical analyses are performed in details and simulation results using PSCAD/EMTDC software are involved to validate the effectiveness of the proposed FCL and its control methods for the soft and fast starting up of IMs.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.