Abstract

In this paper, partial load efficiencies of three types of SOFC combined heat and power systems were calculated by cycle analysis. SOFC means Solid Oxide Fuel Cells. The systems were external fuel reforming system (ER type), internal fuel reforming system (IRa type) and internal fuel reforming system with different configuration (IRb type). In each system, the operating temperature of SOFC was 650◦C. The rated point of electrical power generation of SOFC stack was 560W. Fuel was assumed city gas 13A. At the rated points, results of electrical efficiency by cycle analysis were 39.1%, 41.4% and 41.4% at ER type system, IRa type system, IRb type system, respectively. Electrical efficiency of internal reforming system is higher than that of external system. However, the part load area of IRa type system was narrower than that of ER type system because heat recyle was difficult for IRa type system. The part load area of IRb type system was wider than that of IRa type system due to difference of configuration.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.