Abstract
The authors observed the NaCl concentration of solutions using a near-field microwave microprobe (NFMM). Instead of the usual technique, they take advantage of the noncontact evaluation capabilities of a NFMM. A NFMM with a high Q dielectric resonator allows observation of small variations of the permittivity due to changes in the NaCl concentration. By measuring the reflection coefficient S11, they could observe the concentration of NaCl. The measured signal-to-noise was about 53dB and the minimum detectible signal was about 0.005dB∕(mg∕ml). In order to determine the probe selectivity, they measured a mixture solution of NaCl and glucose.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.