Abstract
Background Incorrect administration of blood products is a critical concern, occurring once in every 12,000 units transfused in the United States. Blood product documentation and scanning are vital for patient safety, yet difficulties in scanning multiple barcodes on blood transfusion bags often lead to delays and the need for manual overrides. Methods This quality improvement project utilized the PDCA (Plan-Do-Check-Act) cycle of improvement to address blood product scanning in a 495-bed hospital in New York City. Results The scanning rate for blood products increased significantly from 69% in January 2021 to 96% in May 2021, representing a 39% improvement. Subsequently, increased compliance in 2022 demonstrated sustainment of best practices. Conclusions Implementation of the PDCA method led to increased compliance in scanning blood product bags following barcode scanner recalibration.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.