Abstract
The bidirectional LLC resonant converter operated at fixed switching frequency is a preferable candidate for a true dc transformer that does not actively control the power flow. This is due to its naturally stiff voltage ratio regardless of the imposed load, its low switching losses, and a stable open-loop behavior. However, in the open-loop operation, determining the required operation direction of the converter is a challenge, which needs to be addressed. This article investigates good design practices for a smooth power direction transition and discusses different strategies for estimating the required operation direction. Moreover, it proposes a new active bridge switchover (ABS) method that is based on an observation of the peak currents in the resonant tank. The proposed method is robust and does not require high precision of the current sensors. The properties of the method are studied using simulations and its practical feasibility is validated experimentally on a low-voltage prototype. This article is accompanied by a video demonstrating the effectiveness of the ABS method in the real time operation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.