Abstract

A miniature device was design for the point-of-care testing (POCT) of tetracycline (TC) including a ratio fluorescence test strip, a sample slot, a UV lamp and a smartphone. The nitrogen and sulfur co-doped carbon dots (N, S-CDs) and Eu3+ were dropped onto the filter paper to construct the ratio fluorescence test strips for the specific detection of TC. Under the excitation at 390 nm, the fluorescence emission of N, S-CDs at 530 nm decreases through inner filter effect (IEF) after addition of Eu3+. When the further addition of TC, the emission of N, S-CDs at 530 nm kept unchanged while the emission of Eu3+ at 616 nm was obviously enhanced for the antenna effect (AE) between Eu3+ and TC. The ratio changes of the two-fluorescence emission realized the quantitative detection of TC. In addition, the test strips with different concentrations of TC showed different fluorescence color from green to red under a 365 nm UV lamp. The miniature device was designed as a fluorescence photo reader with the merits of the powerful functions of smartphones and the portability of test strips. The smartphone camera takes a fluorescent color image of the test strips and the photos are recognized by a color recognizer on the smartphone to obtain RGB (red–greenblue) values which reflect the concentrations of the analytes. Therefore, we established a fast, sensitive and efficient POCT of TC. In particular, the proposed nanomaterial-based POCT platform will open a new route towards the development of ratio fluorescence probe for TC analysis for environment samples.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call