Abstract

Generally, the thermal residual stress which is generated during the curing process of an adhesive significantly decreases the tensile load capability of adhesively bonded joints. In this work, a smart cure cycle with abrupt cooling and postcuring at room temperature was devised to eliminate thermal residual stress and to produce sufficient interfacial wetting. For monitoring and controlling the curing reaction, dielectrometry was used, where the dissipation factor of the adhesive joint was measured. These results showed that the tensile load capability of the adhesively bonded joint fabricated by the smart cure cycle was greatly enhanced because the thermal residual stress was reduced, and sufficient interfacial wetting between the adhesive and adherend was achieved.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.