Abstract
IntroductionBone mineral density (BMD) measured using dual-energy x-ray absorptiometry (DXA) is typically used to assess fracture risk. However, other factors such as bone size and the forward momentum of a fall (a function of body size) can also potentially influence fracture risk, but are understudied. This report describes the characteristics of a cohort of Caucasian pre- and postmenopausal women with distal radius fractures (DRF) after falling onto an outstretched hand.MethodsThe fracture cohort comprised entries in an institutional review board-approved registry of study patients who had had DXA scans. For patients with DRF, the contralateral radius was scanned and BMD, T-scores (used to define bone status as normal, osteopenic, or osteoporotic), and radius width were recorded. Generally, side-to-side (left-right) differences in bone size and BMD are small and, hence, the contralateral radius was considered a surrogate for bone status of the fractured radius. Apparently healthy women without fractures were used as race-, age-, and BMI-matched controls. ResultsPremenopausal women < 49 years of age (mean age, 38 years) with DRF had significanty smaller radii width compared to matched controls. Mean radius BMD was in the normal range. As a group, the cohort was overweight based on mean BMI. Postmenopausal women > 50 years (mean age, 64 years) with DRF also had low radius width, but in contrast to the first group, this group had low peripheral and central BMD.ConclusionsWomen with DRF had contralateral and presumably fractured radii of bone width smaller than matched controls. As a group, these women were also overweight based on BMI. The smaller radius width may increase the risk for fracture irrespective of BMD, especially since larger body size would result in greater inertial force when falling while ambulating.
Highlights
Bone mineral density (BMD) measured using dual-energy x-ray absorptiometry (DXA) is typically used to assess fracture risk
Premenopausal women < 49 years of age with distal radius fractures (DRF) had significanty smaller radii width compared to matched controls
Mean radius BMD was in the normal range
Summary
The objective of this study was to summarize and compare demographic and DXA data between women with DRFs, and race-, age-, and BMI-matched women without fractures
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.