Abstract
The HTV capsule is a High Flux Isotope Reactor (HFIR) target-rod capsule designed to operate at very high temperatures. The graphite containing section of the capsule (in core) is approximately 18 in. (457.2 mm) long and is separated into eight temperature zones. The specimen diameters within each zone are set to achieve the desired gas gap and hence design temperature (900, 1200, or 1500°C). The capsule has five zones containing 0.400 in. (10.16 mm) diameter specimens, two zones containing 0.350 in. (8.89 mm) diameter specimens and one zone containing 0.300 in. (7.62 mm) diameter specimens. The zones have been distributed within the experiment to optimize the gamma heating from the HFIR core as well as minimize the axial heat flow in the capsule. Consequently, there are two 900°C zones, three 1200°C zones, and three 1500°C zones within the HTV capsule. Each zone contains nine specimens 0.210 ± 0.002 in. (5.334 mm) in length. The capsule will be irradiated to a peak dose of 3.17 displacements per atom. The HTV specimens include samples of the following graphite grades: SGL Carbon’s NBG-17 and NBG-18, GrafTech’s PCEA, Toyo Tanso’s IG-110, Mersen’s 2114, and the reference grade H-451 (SGL Carbon). As part of the pre-irradiation program, the specimens were characterized using ASTM Standards C559 for bulk density, and ASTM C769 for approximate Young’s modulus from the sonic velocity. The probe frequency used for the determination of time of flight of the ultrasonic signal was 2.25 MHz. Marked volume (specimen diameter) effects were noted for both bulk density (increased with increasing specimen volume or diameter) and dynamic Young’s modulus (decreased with increasing specimen volume or diameter). These trends are extended by adding the property versus diameter data for unirradiated AGC-1 creep specimens (nominally 12.5 mm-diameter by 25.4 mm-length). The relatively large reduction in dynamic Young’s modulus was surprising given the trend for increasing density with increasing volume. The graphite-filler particle size was noted to be influential in the volume dependency data, with finer grained graphites showing the least specimen volume/diameter effect. Here the volume dependency trends are discussed in terms of the graphite’s filler-particle size and texture.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.