Abstract

In this research, we suggest a method to reduce the loss of the pump aiming to develop small and high-pressure pump for EHA. To reduce the loss of the pump, we focused on the internal leakage loss and the viscous friction loss. We formulated each loss and found that it is effective for loss reduction to make gaps inside the pump narrower and increase the discharge amount per 1 rad making the radius of the gear small. Based on the above, we developed the improved involute external gear pump. Compared with conventional trochoid pump, the internal leakage loss of developed pump is reduced by 22.4% at 10MPa and the viscous friction loss is reduced by 85.6% at 10MPa. Also, there is a problem that internal leakage increases when the internal pressure becomes high. This problem is caused by the deformation of the pump-casing under high pressure. We developed highly rigid ceramics-casing to reduce the increase of the internal leakage. Compared with the pump using aluminum-casing, the pump using ceramics-casing reduced 56.2% in internal leakage loss when the internal pressure increased from 3MPa to 6MPa.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.