Abstract
A procedure is established for the small-signal modelling of n-connected current-programmed parallel-input/series-output pulse-width modulated bridge-based buck dc–dc converters operating in the continuous-current conduction mode. State-space averaging is used to represent the power stage while current-mode control is modelled using a modified new continuous-time technique. Approximate analytical expressions of the major small-signal transfer functions that include the number of modules as a variable are proposed. PSpice simulations are carried out to validate the analysis.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.