Abstract

Pulse frequency modulation (PFM) includes constant on-time (COT) modulation and constant off-time (CFT) modulation. Digital V2 control technique includes digital peak voltage (DPV) control and digital valley voltage (DVV) control. In this paper, DVV controlled buck converter with COT modulation and DPV controlled buck converter with CFT modulation are studied. Their control algorithms are introduced in detail. Based on which, small-signal models of digital PFM V2 controlled buck converter are derived. Small-signal analysis is subsequently performed and compared between these two control methods.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.