Abstract
Mechanical properties of the austenitic steel 316L (both solution annealed and cold worked) and the low activation martensitic steel Optifer have been investigated by small punch tests. The samples, in the form of TEM disks, were irradiated in the target of the spallation source SINQ to displacement doses of up to 11 dpa. Values for yield strength, ductility and fracture energy as evaluated from punch tests are given.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.