Abstract

BackgroundThe American Society of Nuclear Cardiology and the Society of Nuclear Medicine state that incorporation of attenuation-corrected (AC) images in myocardial perfusion scintigraphy (MPS) will improve image quality, interpretive certainty, and diagnostic accuracy. However, commonly used software packages for MPS usually include normal stress databases for non-attenuation corrected (NC) images but not for attenuation-corrected (AC) images. The aim of the study was to develop and compare different normal stress databases for MPS in relation to NC vs. AC images, male vs. female gender, and presence vs. absence of obesity. The principal hypothesis was that differences in mean count values between men and women would be smaller with AC than NC images, thereby allowing for construction and use of gender-independent AC stress database.MethodsNormal stress perfusion databases were developed with data from 126 male and 205 female patients with normal MPS. The following comparisons were performed for all patients and separately for normal weight vs. obese patients: men vs. women for AC; men vs. women for NC; AC vs. NC for men; and AC vs. NC for women.ResultsWhen comparing AC for men vs. women, only minor differences in mean count values were observed, and there were no differences for normal weight vs. obese patients. For all other analyses major differences were found, particularly for the inferior wall.ConclusionsThe results support the hypothesis that it is possible to use not only gender independent but also weight independent AC stress databases.

Highlights

  • The American Society of Nuclear Cardiology and the Society of Nuclear Medicine state that incorporation of attenuation-corrected (AC) images in myocardial perfusion scintigraphy (MPS) will improve image quality, interpretive certainty, and diagnostic accuracy

  • Several studies have reported an increase in the diagnostic accuracy for the detection of coronary artery disease when MPS is attenuation corrected (AC) [6,7,8,9,10,11,12]

  • The American Society of Nuclear Cardiology and the Society of Nuclear Medicine conclude in their joint position statement from 2004 [6] that incorporation of AC in addition to ECG gating with MPS images will improve image quality, interpretive certainty, and diagnostic accuracy

Read more

Summary

Introduction

The American Society of Nuclear Cardiology and the Society of Nuclear Medicine state that incorporation of attenuation-corrected (AC) images in myocardial perfusion scintigraphy (MPS) will improve image quality, interpretive certainty, and diagnostic accuracy. The American Society of Nuclear Cardiology and the Society of Nuclear Medicine conclude in their joint position statement from 2004 [6] that incorporation of AC in addition to ECG gating with MPS images will improve image quality, interpretive certainty, and diagnostic accuracy. These combined results are anticipated to have a substantial impact on improving the effectiveness of care and lowering health care costs. Commonly used software packages for MPS usually only include a normal stress database for non-attenuation corrected (NC) images

Objectives
Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call