Abstract

Efforts to reduce the amount of ultrafine bypass in classifying cyclones by decreasing water recovery increased the particle size cut point and negatively affected classification efficiency due to the impact on slurry rheology. The addition of a viscosity modifier to the feed stream of a classifying cyclone improved the classification performance and decreased the particle size cut point over a range of feed solids concentrations. The detailed test program investigated the use of the modifier in conjunction with varying apex diameters to identify conditions that minimize ultrafine bypass. With small apex sizes, roping conditions were readily eliminated by the addition of viscosity modifiers.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.