Abstract

Dewatering tests were carried out at the Cesenatico sewage treatment plant to point out the influence of phosphorus removal on sludge characteristics, using either aluminium or ferrous sulphate. Equipment performance was studied in different conditions to determine the influence of machine operational variables. As far as centrifugation is concerned, the results showed that the most significant variables the dewatered sludge concentration depends on are the beach residence time and liquid ring height. The feed sludge concentration proved a significant variable if all the data obtained in the three phases are considered together. A pressure filtration model for the prediction of final cake concentration was set up based on the correlations of coefficients a and b of the filtrate flow curve ( φ = a· t b ) with sludge characteristics (concentration, specific resistance to filtration) and with maximum operating pressure.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.