Abstract

On-site domestic wastewater treatment systems (DWTS) are used by a significant fraction of the world's population and are used by one third of the population in Ireland. The effective operation of these DWTS requires regular desludging and so knowledge of expected filling rates is essential for both the homeowner as well as the municipalities which accept this sludge in licensed premises; yet few studies have attempted to quantify the sludge accumulation in such decentralized systems. Field studies were carried out on 27 septic tanks across Ireland to quantify sludge accumulation rates from which optimum desludging frequencies for use in Ireland have then been determined. Sludge accumulation was found to be very high in the first 12 months of system operation (approximately 250 L/person/y) but dropped off to below 150 L/person/y after 2 years. Such volumetric accumulation rates appear high compared to the few other reported international studies; however, measured solids accumulation rates, were low compared to international estimates, ranging from 1 to 10 kg/person/y. An equation for optimal desludging frequencies between 3 and 5 years has been formulated for various tank sizes and occupancy based on the Irish field data and previous international research - 5 years being the maximum allowable interval between desludging before the limiting volume of 50% sludge in the tank is reached.