Abstract
A positron lifetime study has been done on dielectric multilayer cavity mirrors for free-electron-laser experiments by the use of a variable-energy pulsed positron beam. A long-lived ortho-positronium component has been observed at low positron energy region, corresponding to the depth of the top amorphous SiO2 layer. The intensity of the positronium component correlates with the degradation and restoration of the mirrors. We discuss the relation between the positronium intensity and degradation mechanism of the mirrors. The present studies revealed that the slow positron lifetime technique is highly sensitive to the properties of the mirrors and is useful for the evaluation of the mirrors.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Radioanalytical and Nuclear Chemistry Articles
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.