Abstract

Two different schemes are used for the slow beam extraction from the main ring of KEK-PS. One uses the internal target scattering under the non-resonant condition and the other the half-integer resonance at υx = 7.5. The extraction efficiency is higher for the resonant extraction (99 %) than for the non-resonant scheme (~30 %). The spill feedback system are provided to suppress the intensity modulation of the extracted beam and to obtain the spill duration up to 400 msec. Slow extraction also shares the beam with the internal target in both schemes in order to perform experiments on both floors at the same time.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.