Abstract

BackgroundPersistent left superior vena cava (PLSVC) is the most common variant of systemic venous drainage. In the absence of the right superior vena cava (RSVC), implantation of a right ventricular pacing lead may be challenging. Therefore specific implantation techniques and experiences in PLSVC are worth reporting.Case presentationWe present a case report of a 90-year-old Caucasian female patient with PLSVC during single chamber pacemaker implantation due to the third-degree atrioventricular block. With common implantation techniques, we did not even reach the right ventricle. Therefore slittable CPS Direct ™ Universal sheath was employed to overcome the acute angle from PLSVC to tricuspid valve and ensure more fixation stability for longer 100-cm right ventricular lead placement.ConclusionThis case demonstrates safe implantation of 100-cm long right ventricular bipolar active fixation pacing lead using common slittable CPS Direct ™ Universal sheath after failed attempts with „C“ and „J“ stylet shaped electrode. This sheath provides different angle towards tricuspid valve and more fixation stability in patient with PLSVC and absent connection to right atrium.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.