Abstract

The most common technical error associated with microvascular anastomotic failure is accidentally snagging the opposite wall and including it in the stitch, thereby reducing the vessel lumen diameter or occluding it altogether. A simple, safe microsuturing technique is described that combines the use of the slip-knot and the suspension technique in a procedure that allows direct visual inspection of suture placement from first to last stitch. This technique is applicable to end-to-end and end-to-side microvascular anastomoses, for thick-walled ducts such as the vas deferens and the fallopian tube, and in laparoscopic suturing.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.