Abstract

In current design codes, the minimum bolt spacing and edge distance for high-strength bolted friction joints are specified based on the bolt diameter, regardless of the plate thickness or steel strength. However, the mechanical performance of joints with a more compact bolt spacing than that given in the current design specifications has been little examined. In this study, the slip and ultimate strength of high-strength bolted joints with a compact bolt spacing and edge distance were investigated. Tensile tests were conducted on friction-type joints with various bolt arrangements. The use of a compact bolt arrangement was not observed to have a negative influence on the slip strength in these tests. The estimated strengths corresponding to the experimentally observed failure modes were found to agree fairly well with the experimental results within a 10% error. A parametric finite element analysis was also conducted to investigate the influence of the bolt arrangement on the slip coefficient. It was concluded that the bolt spacing and edge distance have little influence on the slip coefficient.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.