Abstract

Hip arthrodesis is a treatment option for painful chronic hip conditions. Hip fractures through a previously arthrodesed hip are relatively uncommon as indications for hip arthrodesis are rare. The following case reports on the use of a sliding hip screw and a pelvic reconstruction plate to address arthrodesed hip fracture in an 81-year-old man. The use of a dynamic hip screw in this setting gave us a stable fixed-angle construct with compression across the fracture site, and the addition of a trochanteric side plate added to the stability. The dynamic compression plate with limited bone contact was used to neutralize the construct. This case describes the successful treatment of such an injury in a way not previously described in the literature with the intent of giving the orthopaedic traumatologist another method to approach this rare injury.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.