Abstract

The measurement of specific serum immunoglobulin E (sIgE) and the skin prick test (SPT) are accepted tools in the diagnostic work-up of suspected food allergy. Often only one of the methods is used to determine sensitization; however, it is still under debate whether these two methods can be used interchangeably. To investigate the concordance of SPT and sIgE serum assays with regard to suspected food allergy. In 395 children referred to our clinic with suspected cow's milk allergy and in 268 children with suspected hen's egg allergy specific immunoglobulin E (IgE) was measured, a SPT and an oral food challenge performed. A weal size≥3mm and sIgE≥0.35 kU/L were considered positive. The weal size of the SPT and the level of food-specific IgE were tested for correlation for each allergen. Of the 395 (23%) children orally challenged with cow's milk, 92 showed no corresponding results for SPT and sIgE as either positive or negative. For hen's egg, in 27 of 268 (10%) children differing test results for SPT and sIgE in serum were obtained. Moreover, regarding the quantitative values for sIgE and SPT in children with or without clinically relevant food allergy, sIgE and SPT correlated badly. The concordance between SPT and sIgE is surprisingly low for cow's milk and hen's egg on an individual basis. Therefore, the tests should not be used interchangeably. Especially in children who receive a negative test result the alternative test should also be used. Furthermore, our data indicate again that oral food challenges are still the method of choice to diagnose food allergies.