Abstract

Damage thresholds (ED<sub>50</sub>) for skin using Yucatan mini-pig (Sus scrofa domestica) have been determined at the operational wavelength of 1319 nm with beam diameters of 0.61 cm and 0.96 cm. Exposure durations of 0.25, 1.0, 2.5 and 10 seconds were used to determine trends in damage threshold with respect to exposure time and beam diameter at this moderately-high penetrating wavelength. A relatively narrow range of total radiant exposure from 37.4 J/cm<sup>2</sup> to 62.3 J/cm<sup>2</sup> average was observed for threshold damage with laser parameters encompassing a factor of two in beam area and a factor of forty in exposure duration.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.