Abstract

We performed a randomized study to compare internal thoracic artery (ITA) flow response to two harvesting methods used in the skeletonization procedure: ultrasonic scalpel and bipolar electrocautery. Sixty patients scheduled for CABG were randomized to receive either ultrasonically (n=30 patients) or electrocautery (n=30 patients) skeletonized ITAs. Intraoperative ITA graft mean flows were obtained with a transit-time flowmeter. ITA flows were evaluated at the beginning (Time 1) and at the end (Time 2) of the harvesting procedure. Post-cardiopulmonary bypass (CPB) flow measurement (Time 3) was obtained in the ITA grafts anastomosed to the left anterior descending artery. Intraoperative mean flow decreased significantly within ultrasonic group (Group U) and electrocautery group (Group E) at the end of the harvesting procedure (P<0.0001 in both cases). Within both groups the final mean flow measured on anastomosed ITAs (Time 3) was significantly higher than the beginning ITA flow value (Time 1). No statistical difference was noted comparing ITA flows between the two groups at any time of evaluation. Skeletonization harvesting of the ITA produces a modification of the mean flow. The quantity and the reversibility of this phenomenon, probably related to vasospasm, are independent from the energy source used in the skeletonization procedure.