Abstract

The MDO (Mehrdraht Dortmund Oberfläche)oxygen electrode was used for studies of tissue oxygen pressure fields (presented as histograms) in healthy human volunteers breathing room air and gas mixtures with different oxygen concentrations. Forearm blood flow measurements were performed with strain gauge plethysmography, and local blood flow and permeability-surface area product (PS) were studied by the clearances of 133xenon and 51Cr-EDTA. At ordinary arterial oxygen pressure levels the histograms were normal, i.e. their distribution type was approximately Gaussian. Higher arterial oxygen pressures caused changes in tissue oxygenation. However, at arterial oxygen pressure levels above 31 kPa two types of abnormal histogram distribution types were distinguished: scattered multi-population histograms (type a) and a type with predominantly low values (type b). Mean forearm blood flow showed only minor variations, whereas the clearances of 133xenon and 51Cr-EDTA were higher with higher PaO2. A parallel increase was also seen in PS.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.