Abstract

A stand-alone photovoltaic power system is designed to operate residential appliances such as fluorescent lamp, and ceiling fan using standard methods. The total load is estimated for twelve hours of operation per day. The battery is sized considering different factors that affect battery efficiency to reliably operate the estimated loads during a sequence of below average insolation. The minimum battery size is obtained to be 130Ah, 12V. The PV array is sized to operate the load on a daily basis based on average weather conditions. The array is sized to proper values in order to operate the estimated load reliably in the month of minimum insolation taking into account different types of power losses.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.