Abstract

In this paper, the axial loading fatigue tests are at first conducted on specimens ofG20Mn5QT steel from axle box bodies in high-speed trains. Then, the size and shape effects on fatigue behavior are investigated. It is shown that the specimen size and shape have an influence on the fatigue performance of G20Mn5QT steel. The fatigue strength of the hourglass specimen is higher than that of the dogbone specimen due to its relatively smaller highly stressed region. Scanning electron microscope observation of the fracture surface and energy dispersive X-ray spectroscopy indicate that the specimen size and shape have no influence on the fatigue crack initiation mechanism. Fatigue cracks initiate from the surface or subsurface of the specimen, and some fracture surfaces present the characteristic of multi-site crack initiation. Most of the fatigue cracks initiate from the pore defects and alumina inclusions in the casting process, in which the pore defects are the main crack origins. The results also indicate that the probabilistic control volume method could be used for correlating the effects of specimen size and shape o the fatigue performance of G20Mn5QT steel for axle box bodies in high-speed trains.