Background:This randomized controlled study evaluated the success rate of insertion and the associated oropharyngeal morbidity for sizes 1.5,2 and 2.5 of ProSeal™ laryngeal mask airway (PLMA) using an alternative digital technique (D) with conventional technique using the introducer tool (IT) technique.Methods:After approval from the hospital ethics committee, 250 healthy children, 6-months to 10 years of age, undergoing elective sub-umbilical surgeries, were included and randomly allocated to D and IT groups for PLMA insertion. The standard anaesthesia protocol was followed. The primary outcomes were success rate of insertion at first attempt and blood on device on removal and the secondary outcomes were oropharyngeal leak pressure and gastric tube placement.Results:The success rate of PLMA insertion at first attempt for sizes 1.5 and 2 did not differ between the two groups. However, for size 2.5, it was significantly lower than that for the other two sizes in both groups. The incidence of blood on device was higher with the 2.5 airway in both groups, reaching statistical significance only in group D. Other parameters did not differ between the two groups.Conclusion:We conclude that size 2.5 PLMA is associated with a lower success rate of insertion and a higher incidence of blood on device using both techniques. Insertion of PLMA sizes 1.5 and 2 by an alternative digital technique is comparable to the IT technique.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.