Abstract
This study was conducted to evaluate the short- and long-term clinical and angiographic results of implantation of a flexible, coiled stainless steel stent, the Freedom Coronary Stent. During the study period this stent was used as an alternative to the Palmaz-Schatz PS153 coronary stent in long or tortuous lesions. The study was designed as a prospectively planned outcome analysis. Implantation of Freedom stents was attempted in 62 consecutive patients (56% males, mean age 63+/-10 years) with a total of 65 coronary lesions. Indications for stent implantation were: restenosis, 8%; recoil, 26%; visible dissection, 32%; threatening occlusion, 15%; chronic total occlusion, 18%. The average stent length was 30+/-16 mm and 67% of the lesions were type C. Rate of successful stent implantation, acute complications, angiographic restenosis after 6 months and major cardiac events (death, myocardial infarction, target vessel revascularization) during follow-up were assessed. The success rate of stent implantation was 94%. One patient died after an emergency bypass operation and one patient suffered a subacute stent thrombosis, which was successfully treated with re-percutaneous transluminal coronary angioplasty (PTCA). There were no Q- or non-Q myocardial infarctions. Clinical follow-up was carried out in 56 patients (97%) and 57 vessels were assessed by angiography (93%). Mean length of the follow-up period was 6.8+/-2.3 months. During the 6 months' follow-up period, one patient died, two patients suffered an acute non-Q myocardial infarction and eight patients had revascularization of the target vessel. Major cardiac event rate for all patients where stent implantation was intended was 23%. Angina CCS class declined from 3.0+/-0.9 to 1.1+/-0.8 (p < 0.01) before PTCA to follow-up. Overall restenosis rate was 28%. In 14 lesions with a stented segment length of <20 mm, the restenosis rate was 21%; in 31 lesions with a stented segment length > or =20 and <30 mm, the restenosis rate was 26%; and in 13 lesions with a stented segment length of > or =30 mm, the restenosis rate was 42%. Although there was a high procedural success rate after implantation of the Freedom stent in long or tortuous lesions, problems with high restenosis rates in long lesions remain unresolved.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.