Abstract
This paper discusses a rectifier inverter composed of two three-leg converters with equal and unequal dc-links voltages connected in series. The operation with equal dc-links voltages divides equally the voltages in each converter. On the other hand, the operation with unequal dc-links voltages increases the number of voltage levels and contributes to reduce harmonic distortion and power losses. Space-vector and level-shifted techniques are discussed. The balance of separated dc sources using redundant voltage vectors is addressed in this paper. A closed-loop controller is used to control the average value of the dc voltages. Simulation results compare power losses and harmonic distortion of three-leg and six-leg topologies. Experimental results are provided to validate the feasibility of the system.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.