Abstract

Power factor default is 0.85. if the power factor is less then 085, it will cause a loss to the user. In addition, the low value of the power factor will cause the maximum power capacity not to be used. Therefore designed a monitoring tool and improvement of power factors in household electricity consumption via SMS. This tool is constructed using a combination of current sensor, voltage sensor to determine the work of monitoring system for the use of current, voltage, power, and the value of power factor in household electricity consumption. In addition, bank capacitors are used to repair on increase the value of power factors and the GSM SIM 800L module is used to sending SMS from the system to the user so that the use of household electricity consumption can be monitored ini real time. Testing is done at home using household loads, namely blender, mixers, CRT TV, refrigerator and washing machines. The test results obtained are the percentage increase in the value of the average power factor of 27.12 % and after an improvement in the power factor using a capacitor bank can save costs by about 22 % and able to monitor by SMS so this shows that this tool is able to monitor and improve the power factor efficiently

Highlights

  • If the power factor is less 085, it will cause a loss to the user

  • Designed a monitoring tool and improvement of power factors in household electricity consumption via SMS. This tool is constructed using a combination of current sensor, voltage sensor to determine the work of monitoring system for the use of current, voltage, power, and the value of power factor in household electricity consumption

  • Bank capacitors are used to repair on increase the value of power factors and the GSM SIM 800L module is used to sending SMS from the system to the user so that the use of household electricity consumption can be monitored ini real time

Read more

Summary

Introduction

If the power factor is less 085, it will cause a loss to the user. In addition, the low value of the power factor will cause the maximum power capacity not to be used.

Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.