Abstract
A single-pulse, laser-saturated fluorescence technique has been developed for absolute OH concentration measurements with a temporal resolution of 2 nsec, a spatial resolution of <0.1 mm(3), and an estimated accuracy of +/-30%. It has been applied in laminar, transitional, and turbulent hydrogen-air diffusion flames, providing the first reported quantitative measurements of average values, rms fluctuations, and probability density functions of OH radical concentration in nonpremixed flames.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.