Abstract
This paper provides a special flexible graphene film based capacitive wireless power transfer (FGCPT) system for powering biomedical sensors of smart wearable devices. The graphene conductive material is flexible, transparent, highly conductive, and impermeable to most gases and liquids. Generally, the coupling structure of capacitive wireless power transfer (CPT) system is consisted of metal plates. However, it is hard to use for the biomedical sensors as the low power density and big volume. The shape of graphene conductive material could be easily built and changed according to the application requirements. In this paper, the power supply of biomedical sensing system could be accomplished by a single graphene film which is acted as the receiver of FGCPT system. The 200 mW power level is achieved with the maximum 9 V output voltage. The theory and calculation are verified by the simulated and experimental results.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IEEE Transactions on Biomedical Circuits and Systems
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.