Abstract

BackgroundKnee osteoarthritis associated with extra-articular deformity (EAD) can confront the arthroplasty surgeons with challenges of bone resection and soft tissue balancing. The aim of this study was to describe a single-stage procedure associating corrective osteotomy with total knee arthroplasty (TKA), and to determine the outcome at mid- to long-term follow-up.MethodsA total of seven patients (seven knees) with knee osteoarthritis and supracondylar deformity were included in this study. Six patients were female, and one was male, with the median age of 62 years (range, 37-76 years). All patients were treated with single-stage TKA and femoral osteotomy. Osteotomy was fixed with long cemented stem. Hospital of Special Surgery (HSS) scores, collateral ligament laxity, and range of motion (ROM) were clinically evaluated preoperatively and at each follow-up. Radiographic parameters including the mechanical axis deviation (MAD), mechanical lateral distal femoral angle (mLDFA), mechanical proximal tibial angle (mMPTA), and joint line congruence angle (JLCA) were also measured. The occurrence of perioperative complications was recorded.ResultsThe median follow-up time was 91 months (range, 38-104 months). At the last follow-up, all components were stable and no patients required revision. Nonunion of the osteotomy occurred in one patient. In all patients, the lower limb mechanical alignment improved greatly. The mean angle of MAD was restored from 10.49±6.05 cm preoperatively to 1.11±4.97 cm postoperatively. The 90° mLDFA was almost acquired in all cases, with the postoperative value of 90.79±2.40°. After operation, the mMPTA improved from 84.18±6.13° to 91.33±3.13°. The JLCA changed from 2.94±1.61° to −0.71±3.50°. The median HSS score improved from 45 (range, 34-56) preoperatively to 90 (range, 82-97) postoperatively, with the outcome of all patients rated good to excellent. The median ROM improved from 70° (range 0–110°) preoperatively to 105° (range 90–125°) postoperatively. No instability of knee joint was observed. Complications included an intraoperative split fracture of distal femur and one case of wound exudation resulting from fat liquefaction.ConclusionsFor knee osteoarthritis with femoral supracondylar deformity, single-stage TKA and corrective osteotomy was feasible but technically demanding. The use of long cemented stem for osteotomy fixation can provide reliable rotational control of the bone segments.

Highlights

  • Knee osteoarthritis associated with extra-articular deformity (EAD) can confront the arthroplasty surgeons with challenges of bone resection and soft tissue balancing

  • At 6 months after operation, the osteotomy site healed in 6/7 cases

  • Nonunion of the osteotomy occurred in one patient, but without pain and any discomfort

Read more

Summary

Introduction

Knee osteoarthritis associated with extra-articular deformity (EAD) can confront the arthroplasty surgeons with challenges of bone resection and soft tissue balancing. Advanced osteoarthritis associated with these deformities can confront the arthroplasty surgeons with challenges of bone resection and soft tissue balancing [1, 2]. Regarding EAD on femur, an extensive release can balance the knee in extension but will, possibly, cause laxity on the released side in flexion This will lead to instability or compromise on the rotational mal-positioning of the femoral component. Severe sagittal or rotational deformity is difficult to compensate by the position of the component Under those complex circumstances, corrective osteotomy to normalize long-bone anatomy is prudent

Objectives
Methods
Results
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.