Abstract
The main features of ECR ion sources (high efficiency, almost unlimited lifetime, stable running conditions, low ion energy spread) make them, when optimized for a high yield at charge state 1+, ideally suited for on-line mass separation. For this reason a single stage 6.4 GHz test source was built for the Paul Scherrer Institute medical radioisotope production facility. Source geometry and operation conditions were optimized for the mass separation of xenon isotopes. Different support gases were tested and an ionization efficiency of 60% for Xe+ was achieved with H2 as support gas. The best results were found at a source pressure of 5×10−4 mbar and at a microwave power level of about 100 W. At an axial magnetic field of about 3 kG the mirror ratio showed no strong effect on the general performance of the source. Our tests showed the advantages of the ECR source type for the mass separation of gaseous isotopes in terms of efficiency and reliability.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.