Abstract

A single-stage pulse tube refrigerator driven by a 7 kW scroll compressor is equipped with a set of solenoid valves such that two different operational modes can be realised, namely a 4-valve configuration and an active buffer configuration. Typical refrigeration loads of 100 W at 57 K are achieved for both modes. In the 4-valve configuration, no-load temperatures down to 24.6 K are reached with the optimal valve settings for 57 K load measurements. In this paper both systems are compared with respect to various operational parameters.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.