Abstract

An experimental study has been conducted to evaluate the influence of the presence of inner tube and the Rayleigh number on free convective heat transfer in an open thermosyphon. Water and fluorocarbon R-11 refrigerant as the working fluids were utilized. Heat transfer results using the concentric geometry were given for modified Rayleigh number from 3.6×102 to 4.1 × 107 which encompasses the regions of similarity, impeded and boundary layer flow conditions. It was found that the presence of the inner tube markedly increases the overall heat transfer coefficient of open thermosyphon by a factor as large as 2 to 10 in the turbulent impeded and boundary layer regimes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.