Abstract

Abstract The single phase heat transfer from an upward facing, 100 cm 2 (0.01 m 2 ) copper surface, to square arrays of impinging water sprays was experimentally investigated. Three models of commercially-available full-cone pressure nozzles, of varying flow and pulverization characteristics, were used in runs where average impinging coolant mass flux covered the 0.28–7.2 kg/m 2 s range. Array geometry was varied by adjusting nozzle-to-nozzle and nozzle-to-impingement surface distances. Experimental apparatus construction allowed for good drainage of spent coolant and unrestricted air entrainment to spray cones. The area-averaged heat transfer coefficient was found to be a strong function of coolant mass flux. Droplet Sauter mean diameter and nozzles discharge velocity appear to have secondary effects on the single phase heat transfer. Only one single geometric aspect ratio was found necessary for correlating measured data. The proposed correlation agreed with the experimental data within 18.9% error bounds (mean absolute error of 6.29%).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.