Abstract

PurposeThere is no standardized single-incision laparoscopic cholecystectomy (SILC) technique in contrast to robot single-site cholecystectomy (RSSC). We tried to implement the array of instruments used in RSSC to SILC.MethodsA series of 108 consecutive patients underwent SILC between September 2014 and July 2017 by 2 surgeons. The indication was benign disease of the gallbladder. The perioperative outcomes were reviewed. We used the 4-channel Glove port and conventional laparoscopic instruments.ResultsThe study subjects consisted of 29 males and 79 females, and the mean age was 44.4 years (range, 16–70 years). Mean body mass index was 24.1 kg/m2. The mean working time was 25.0 ± 10.7 minutes and total operation time was 44.4 ± 12.4 minutes. There were 7 cases of conversion (additional 1 port in 4 patients, additional 2 ports in 2, and conventional 4 port technique in 1). Bile spillage from the gallbladder during the procedure occurred in 17 (15.7%). There were no postoperative complications. Postoperative hospital stay was 2.0 ± 0.6 days.ConclusionThe alignment of the instruments in a RSSC was successfully implemented into a SILC, so that an equally effective operation was possible.