Abstract

We analyzed jitter recordings made with concentric needle electrode (CNE) single-fiber electromyography (SFEMG) in Lambert-Eaton myasthenia (LEM). Fifteen subjects diagnosed with LEM were studied using CNE-SFEMG in the extensor digitorum (ED) and tibialis anterior (TA) muscles. CNE-SFEMG in the ED and TA was also used to evaluate 12 and 10 healthy controls (HCs), respectively. Ten men and 5 women were diagnosed with LEM based on an increase of 100% in compound muscle action potential amplitude during 50 Hz repetitive nerve stimulation. All patients exhibited markedly greater jitter in the ED (88.8 ± 23.2 µs) and TA (92.2 ± 30.2 µs) than HCs (28.3 ± 3.4 µs and 30.9 ± 5.1 µs, respectively). CNE-SFEMG is sensitive for discovering abnormalities in neuromuscular transmission in LEM. Muscle Nerve 56: 253-257, 2017.