Abstract

PurposePrevious nonlinear gradient research has focused on trajectories that reconstruct images with a minimum number of echoes. Here we describe sequences where the nonlinear gradients vary in time to acquire the image in a single readout. The readout is designed to be very smooth so that it can be compressed to minimal time without violating peripheral nerve stimulation limits, yielding an image from a single 4 ms echo.Theory and MethodsThis sequence was inspired by considering the code of each voxel, i.e. the phase accumulation that a voxel follows through the readout, an approach connected to traditional encoding theory. We present simulations for the initial sequence, a low slew rate analog, and higher resolution reconstructions.ResultsExtremely fast acquisitions are achievable, though as one would expect, SNR is reduced relative to the slower Cartesian sampling schemes because of the high gradient strengths.ConclusionsThe prospect that nonlinear gradients can acquire images in a single <10 ms echo makes this a novel and interesting approach to image encoding.

Highlights

  • Several groups, including our own, have studied whether the geometry of gradient encoding can better complement the information from locally sensitive receivers. [12,13,14,15,16,17] Previous work has looked at whether this allows a further reduction in the minimum number of echoes due to increased encoding efficiency when the encoding is shared between the magnetic field gradients and the receiver coil sensitivity profiles

  • This has led to many studies of image encoding with nonlinear gradient shapes, producing good image reconstructions from highly undersampled datasets. [12,13,14] Previous nonlinear gradient encoding work has explored single shot trajectories employing EPI-like readouts

  • This linearized trajectory reduces the maximum slew rate on each channel and would theoretically allow us to acquire the data in 4.3 ms without exceeding the mean threshold for peripheral nerve stimulation discomfort (55T/s) over a 20 cm field of view

Read more

Summary

Introduction

The use of locally sensitive receivers to provide encoding, typically aims to reduce scan time by reconstructing images from a reduced number of timepoints.[1,2,3,4,5,6,7,8,9,10,11] To facilitate this, several groups, including our own, have studied whether the geometry of gradient encoding can better complement the information from locally sensitive receivers. [12,13,14,15,16,17] Previous work has looked at whether this allows a further reduction in the minimum number of echoes due to increased encoding efficiency when the encoding is shared between the magnetic field gradients and the receiver coil sensitivity profiles. [12,13,14,15,16,17] Previous work has looked at whether this allows a further reduction in the minimum number of echoes due to increased encoding efficiency when the encoding is shared between the magnetic field gradients and the receiver coil sensitivity profiles. This has led to many studies of image encoding with nonlinear gradient shapes, producing good image reconstructions from highly undersampled datasets. Pixels with redundant or similar timecourses have an azimuthal symmetry that can be distinguished via receiver coil encoding

Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.