Abstract
Aim To evaluate contrast-enhanced ultrasound (CEUS) as an effective alternative to CT-angiography (CTA) for endoleak detection and aneurismal sac diameter measurement in the follow-up after endovascular abdominal aortic aneurysm repair (EVAR). Methods From January 2006 to December 2010, 395 patients underwent EVAR follow-up with both CTA and CEUS. The diameter of the aneurismal sac and the presence of endoleaks were evaluated in all the 395 paired examinations. Results Bland–Altman plots showed a good agreement in aneurismal sac diameter evaluation between the two imaging modalities. The mean diameter was 54.93 mm (standard deviation (SD) ±12.57) with CEUS and 56.01 mm (SD ± 13.23) with CTA. The mean difference in aneurismal sac diameter was −1.08 mm ± 3.3543 (95% confidence interval (CI), −0.75 to −1.41), in favour of CTA. The number of observed agreement in endoleak detection was 359/395 (90.89%). The two modalities detected the same type I and type III endoleaks. McNemar’s χ 2 test confirmed that CTA and CEUS are equivalent in endoleak detection. Conclusions CEUS demonstrated to be as accurate as CTA in endoleak detection and abdominal aortic aneurysm diameter measurements during EVAR follow-up, without carrying the risks of radiation exposure or nephrotoxicity. Even if it cannot be proposed as the sole imaging modality during follow-up, our analysis suggests that it should have a major role.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: European Journal of Vascular and Endovascular Surgery
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.