Abstract
Previous studies have used cardiopulmonary exercise test (CPET) data to objectively assess physiological changes in patients undergoing percutaneous pulmonary valve implantation. A retrospective review was performed to assess pre- and post-CPET data among patients undergoing Alterra Adaptive Prestent and SAPIEN 3 transcatheter heart valve (Alterra) placement. Of the 7 patients eligible for the study, 5 (71%) were male. The mean age was 22 years (range: 12-49 years). CPET data showed significant (P= 0.03) improvement in ventilatory efficiency (VE/VCO2) while only 2 (29%) patients had an improvement of percent predicted peak oxygen consumption (VO2). These findings suggest favourable haemodynamic changes though further investigation is needed.