Abstract
Single-phase cascade multilevel inverters (CMI) allow to feed loads with multiple voltage levels, which reduces the total harmonic distortion (THD) when compared with traditional three-level inverters. Reducing the THD makes the filter size smaller and cheaper which contributes to improve the overall performance of the power converter. These advantages make CMI attractive in several applications like: photovoltaic (PV) systems, active filtering, motor drives, among others. Transformerless grid-connected PV systems require a specific design of the pulse width modulation (PWM) strategy in order to deal with the common mode current (CMC) issue. Then, five levels CMI can be controlled by using different PWM strategies since the electrical circuit can be configured in multiple combinations. In this paper, a PWM sequence is proposed in order to deal with CMC issue in a CMI devoted to transformerless PV systems. Numerical and experimental results show the proper operation of the inverter and the reduction of the CMC.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.