Abstract

Chrysanthemum-like titanium nitride (CL-TiN) was fabricated at 800°C through ammonia nitridation treatment of TiO2 precursor. An electrochemical biosensor based on the glassy carbon electrode modified with TiN (CL-TiN/GCE) was prepared for the simultaneously detection of ascorbic acid (AA) and uric acid (UA). Excellent results are obtained for the separate quantification of UA and AA by differential pulse voltammetry due to the special structure and large surface area of TiN. The detection limits of the electrochemical sensor are 1.52μM and 0.28μM for AA and UA (S/N=3), and the working linear ranges for AA and UA are 50–1500μM and 10–300μM, respectively. This sensor also exhibits outstanding anti-interference ability toward co-existing molecules with good stability, sensitivity and reproducibility. The present work opens a new window for simultaneous detection of AA and UA based on the CL-TiN/GCE.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call