Abstract

Trajectory-based treatment planning involves the combination of a gantry-couch trajectory with volumetric modulated arc therapy (VMAT) treatment plan optimization. This work presents the implementation of an optimization methodology that generates a trajectory simultaneous with treatment plan optimization (simTr-VMAT). The optimization algorithm is based on the column generation approach, in which a treatment plan is iteratively constructed through the solution of a subproblem called the "pricing problem." The property of the pricing problem to rank candidate apertures based on their associated price is leveraged to select an optimal aperture while simultaneously determining the trajectory path. A progressively increasing gantry-couch grid resolution is used to provide an initial coarse sampling of the angular solution space while maintaining fine control point spacing with the final treatment plan. The trajectory optimization was applied and compared to coplanar VMAT treatment plans for a lung patient, a glioblastoma patient, and a prostate patient. Algorithm validation was performed through the generation of 5000 random trajectories and optimization using column generation VMAT for each patient case, representing the solution space for the trajectory optimization problem. The simTr-VMAT trajectories were compared against these random trajectories based on a quality metric that prefers trajectories with few control points and low objective function value over long, inefficient trajectories. For the lung patient, the simTr-VMAT plan resulted in a decrease of the mean dose of 1.5 and 1.0Gy to the heart and ipsilateral lung, respectively. For the glioblastoma patient, the simTr-VMAT plan resulted in improved planning target volume coverage with a decrease in mean dose to the eyes, lens, nose, and contralateral temporal lobe between 2 and 7Gy. The prostate patient showed no clinically relevant dosimetric improvement. The simTr-VMAT treatment plans ranked at the 99.6, 96.3, and 99.4 percentiles compared to the distribution of randomly generated trajectories for the lung, glioblastoma, and prostate patients, respectively. The simTr-VMAT optimization methodology resulted in treatment plans with equivalent or improved dosimetric outcomes compared to coplanar VMAT treatment plans, with the trajectories resulting from the optimization ranking among the optimal trajectories for each patient case.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.