Abstract

The sensitivity of the LM139A quad voltage comparator toward simultaneous single-event transient has been investigated through laser single photon absorption. The results have been supported and compared to heavy-ion tests. The analysis of sensitivity leads to the observation of two sensitive cases related to internal charge-sharing mechanism between comparator function and input line coupling effects.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call