Abstract

Three-dimensional transesophageal echocardiography (3D TEE) is an excellent modality for real-time visualization of the heart and monitoring of interventions. However, 3D TEE segmentation is still a challenging task due to the complex anatomy, the limited field of view, and typical ultrasound artifacts. To improve the usability of 3D TEE for monitoring interventions, we propose to segment all cavities within the TEE view with a multi-cavity Active Shape Model (ASM) derived from Computed Tomography Angiography (CTA) in conjunction with a tissue/blood classification based on a Gamma Mixture Model (GMM). 3D TEE image data of five patients were acquired with a Philips X7-2t matrix TEE probe. Tissue probability maps were estimated by a two class (blood/tissue) GMM. A statistical shape model containing left and right ventricle, left and right atrium and aorta (LV, LA, RV, LA, Ao) was derived from CTA scans of 151 patients by Principal Component Analysis. Models from individual cavities (ASM <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">part</sub> : ASM <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">LV</sub> etc.) and of the whole heart (ASM <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">tot</sub> ) were generated. First, ASM <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">tot</sub> was aligned with the 3D TEE by indicating 3 anatomical landmarks. Second, pose and shape of ASM <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">tot</sub> were iteratively updated by a weighted update scheme excluding parts outside of the image sector. Third, shape and pose of each ASM <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">part</sub> were initialized based on shape and pose of ASM <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">tot</sub> and iteratively updated in a constrained manner to fit the tissue probability maps. All 3D TEE sets were manually outlined in multiple short and long axis views by two observers. The mean outline of both observers was compared to the ASM segmentations by calculating Dice coefficients. All patients had preoperative CTA scans which were segmented using an atlas approach. The TEE and the CTA segmentation were registered and Dice coefficients were computed. The Dice coefficients of the whole heart between the average observer and ASM segmentations were 0.91, 0.75, 0.87, 0.88, and 0.84 (interobserver variability: 0.95, 0.92, 0.92, 0.88, and 0.90) for TEE set 1 to 5 respectively. The Dice coefficient for the whole hart between CTA and TEE segmentation were 0.85, 0.80, 0.80, 0.81, and 0.71 and showed good agreement. In this work we could successfully show the accuracy and robustness of the proposed multi-cavity segmentation scheme.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.